ge:heaters [2024/01/25 21:23] – [Clothes Iron Heater Solution] Alan Shea | ge:heaters [2024/05/29 23:54] (current) – [Generator Anti-Condensation Heater] Alan Shea | ||
---|---|---|---|
Line 14: | Line 14: | ||
<WRAP center round alert 60%> | <WRAP center round alert 60%> | ||
- | **// | + | **// |
</ | </ | ||
Factory-supplied anti-condensation heaters operate at approximately 110C+ but are often mounted on a bracket in front of the exciter. They depend on the heat conduction through the bracket to the generator frame. This does not seem to keep the actual windings warm enough to prevent moisture accumulation in the winding insulation. ((Gensets built to spec provide an opportunity to order the generator with extra insulation treatment of the windings(" | Factory-supplied anti-condensation heaters operate at approximately 110C+ but are often mounted on a bracket in front of the exciter. They depend on the heat conduction through the bracket to the generator frame. This does not seem to keep the actual windings warm enough to prevent moisture accumulation in the winding insulation. ((Gensets built to spec provide an opportunity to order the generator with extra insulation treatment of the windings(" | ||
- | We had tried using regulated heat tape, but the heat output decreases with temperature, | + | We tried using regulated heat tape, but the heat output decreases with temperature, |
=====Clothes Iron Heater Solution=== | =====Clothes Iron Heater Solution=== |
Copyright © Alan Shea, 2011-2025